What are the requirements for elevator door in elevator inspection?

A, elevator inspection of elevator room door routine requirements:

The width and height of the access door of the computer room shall not be less than 0.60m and 1.80m, and the door shall not be opened indoors. Doors should be equipped with locks with keys, which can be opened from the computer room without keys. Outside the door, it should be marked "the computer room is important, no idle people enter", or there are other similar warning signs.

Second, for the requirements of the computer room door fire prevention:

1, in the setting of fire elevator, fire elevator shaft, machine room and adjacent elevator shaft and machine room, when the door is opened on the partition wall, Class A fire doors should be set.

2. The setting of fire elevator shall meet the relevant requirements in the same building code.

3. The elevator machine room door shall be a Class A fire door, and the elevator machine room door shall be a Class B fire door (except those directly open to the outside).

Extended data

Fire rating requirements of elevator machine room

1, the door of the fire elevator machine room, no matter where it is opened, should be a Class A fire door.

2. The doors of the fire elevator room and other elevator rooms shall be Class A fire doors.

3. If the door of the ordinary elevator machine room leads directly to the non-outdoor part such as the walkway, it should be a Class B fire door.

4. When the door of the ordinary elevator room opens directly outward, a fire door should be set.