Joke Collection Website - News headlines - Company elevator emergency plan

Company elevator emergency plan

Company elevator emergency plan (5 general rules)

In normal study, work and life, emergencies are not allowed. In order to avoid more serious consequences, emergency plans are often made in advance according to specific conditions. Then the question is coming, how to write the emergency plan? The following is the company elevator emergency plan (generally 5 articles) I compiled for you, for reference only, and I hope it will help you.

Company's elevator emergency plan 1 In order to further implement the management requirements of the provincial safety supervision bureau, improve the safety awareness of our company and the whole people in using elevators, scientifically and effectively control and handle accidents after accidents, adhere to the principle of "prevention first, self-help first", and conscientiously implement the Regulations on Safety Supervision of Special Equipment in accordance with national safety laws and regulations and various elevator rules and regulations promulgated by the State Administration of Work Safety, do a good job of prevention and reduce the failure rate of elevator use.

I. Purpose

1, through actual combat drills, deepen the understanding of fire safety knowledge and practical skills of correct use of fire equipment by all employees of our company;

2. Further improve the safety awareness of all employees, test the ability of technicians to deal with emergencies, be familiar with the whole rescue operation process and organize cooperation to achieve the actual combat effect of the drill.

3. Strengthen the training of evacuation speed and self-protection ability of personnel at the scene of the accident when an emergency occurs;

4. Further understand the learning, application and mastery ability of key employees and new employees;

5, check the ability to start the emergency rescue, as well as the overall coordination ability and emergency level of all full-time staff in emergencies;

6. Check whether the emergency material reserve of each emergency resource library can meet the needs of emergency rescue.

7. Quickly and effectively carry out emergency rescue of safety accidents in individual units, minimize casualties and property losses, ensure the safety of life and property of enterprise employees, and maintain social stability.

Second, the basis

This plan is formulated in accordance with the Safety Law of People's Republic of China (PRC), Regulations on Safety Supervision of Special Equipment and other relevant laws and regulations, and Guidelines for the Preparation of Emergency Plans for Safety Accidents of Business Units.

Third, the scope of application

This plan is applicable to all elevator users and serious accidents.

Fourth, the emergency plan system

Emergency rescue plan includes two systems: special emergency rescue plan and on-site disposal plan.

Five, emergency work principles

Specializing in many skills, combining peacetime and wartime, and responding quickly. As far as possible, on the basis of the existing professional rescue team, supplement equipment, expand skills and build a multi-functional emergency rescue team; Strengthen the training of part-time rescue forces in enterprises, so that they can carry out rescue quickly, timely and effectively in an emergency and realize the combination of peacetime and wartime.

Six, the existing hazards and risk analysis

Customers trapped in the elevator will suffocate if they are not rescued for a long time. The main reason is that the elevator door lock switch is damaged.

Seven. Time and place of the exercise

Exercise time: xxxx

Exercise location: xxx

Emergency drill route: xxx

Eight, practice content:

Employees' self-help and mutual rescue and elevator emergency rescue drills are the main methods. The specific content is:

(1) alarm drill;

(2) Evacuation and escape drills;

(3) Common on-site procedures of emergency rescue drills.

Nine, emergency rescue organization, composition and division of responsibilities

1. All members of the safety emergency rescue team and some employees of the building.

2. Leadership: The company set up an elevator emergency safety committee, which is headed by general manager Han Ren, and the safety committee is composed of general manager Han, maintenance department Zhang Daifa, engineering department Li Shoujian, Han Lichen and other relevant departments.

3. Responsibilities of the drill site team: Chief Commander: General Manager: Responsible for emergency rescue' Deputy Commander: Maintenance Department: Assist the general manager and be responsible for emergency rescue. Team leader: Responsibilities: responsible for emergency rescue and evacuation, commanding rescue and evacuation team: commanding and leading personnel to evacuate to safety exits. Warning group: responsible for stabilizing the situation at the scene and prohibiting other irrelevant vehicles and personnel from entering the scene. Rescue group: different methods are used for rescue demonstration according to different activities.

Company elevator emergency plan 2 This plan is formulated to improve the community's ability to deal with all kinds of accidental injuries and people trapped during elevator operation, standardize the concrete implementation of community emergency rescue plan, establish and improve the passenger accident emergency system, standardize the community's emergency treatment of injuries and people trapped accidents, and effectively prevent, control and eliminate the harm of elevator injuries and people trapped accidents in time.

1. Any employee who receives the alarm from the owner or finds that there are passengers trapped in the elevator shall immediately notify the security fire control room and record the time of receiving the report and finding.

2. After receiving the report, the security fire control room, on the one hand, knows the location, trapped number, personnel situation and elevator floor through the monitoring system or walkie-talkie, on the other hand, reports to the manager of the order maintenance department or the foreman on duty through the walkie-talkie, requesting to send someone or contact the engineering department for rescue.

3. After receiving the report, the order maintenance department or the foreman on duty will immediately come to the scene in person or send personnel to get in touch with the trapped passengers to comfort them and ask them to stay calm and wait patiently for rescue. Especially when the trapped passengers are frightened or very impatient and try to escape by taking extraordinary measures such as prying the door, they should be patiently warned not to panic and be impatient, and not to take unnecessary actions blindly, so as not to enlarge the fault and cause danger. Note: During this process, no one should be left at the scene. Keep in touch with the trapped people, keep abreast of their mood and health, and report the situation to the general manager or the leader on duty in time.

4. After receiving the report, the engineering department or the personnel on duty should immediately send someone to the scene for rescue, and call the elevator maintenance company for maintenance when necessary. If you can't save yourself, try to take measures to ensure the safety of the trapped passengers and wait for the technicians of the elevator maintenance company to come to the rescue.

5. If the engineering department and the elevator maintenance company are unable to rescue or cannot rescue in a short time, they should ask the public security department or the fire department for help as appropriate (the reasons and circumstances for help should be explained). Before asking the public security fire department for help, you should get the consent of the general manager or the leader on duty.

6. In the process of rescue, if anyone (especially the elderly or children) among the trapped passengers is found fainting or comatose, the medical staff should be immediately notified to be present, so that the trapped passengers can be rescued after being rescued.

7. After the trapped person is rescued, the Minister of Order Maintenance or the foreman on duty should immediately express condolences to him, and understand his physical condition and needs, and ask him to provide his name, address, contact number and the reason for coming to the community. If the trapped person does not cooperate to leave, it shall be recorded and filed.

8. After the trapped person is rescued, the engineering department should immediately ask the elevator maintenance company to find out the cause of the failure, and it can resume normal operation after repair.

9. The order maintenance department or the foreman on duty shall make a detailed record of the incident, including the time when the report was received, the time when the order maintainer and maintenance personnel arrived at the scene, the notice and arrival time of the elevator maintenance company, the rescue time of the trapped people, the basic situation of the trapped people, and the time when the elevator resumed normal operation. If there are public security, fire fighting and medical personnel present, the arrival and departure time and vehicle number should also be recorded separately; If an injured person is trapped, record the situation of the injured person and the hospital he was sent to.

10, the engineering department or the personnel on duty shall record the time, cause, rescue method and repair time of the fault in detail.

Company elevator emergency plan 3 As a means of transportation for people to get up and down floors, elevators should pay more attention to safety issues. In order to ensure the safe, effective and reliable operation of elevator equipment, reduce the impact of accidents and avoid personal injury accidents, Xingtai Elevator formulates this plan. The plan is divided into three stages.

A, accident report disposal procedures

1. When receiving the accident report, the personnel on duty in the engineering department should know the following information from the reporter: the location of the faulty elevator, whether it is trapped or not, which floor it is trapped on, and make records.

2. The personnel on duty in the engineering department shall verify whether the reception is correct to the monitoring room by telephone.

3. After confirming the situation, the personnel on duty in the engineering department immediately rushed to the scene and informed the maintenance unit to arrive at the scene immediately.

4. Personnel with elevator operation qualification should bring the keys of elevator machine room, elevator landing doors, communication tools and maintenance tools to the site for treatment. If necessary, additional personnel will be sent to assist in the duty.

Second, the elevator fault handling procedures

Two fault handlers (1, Party A and Party B) arrive at the elevator machine room and the elevator car floor respectively.

2. Answer: First cut off the main power supply of the elevator, but the car lighting must be maintained. Get in touch with the trapped person through the direct dial telephone in the elevator room, and tell the trapped person to wait for rescue and not to try to leave by himself.

3.b: Use the elevator landing door key to open the elevator landing door for about 30-40 cm, and observe the position of the elevator car.

4. If the car is located within 600cm of the flat floor, the trapped person can leave smoothly, and the landing door can be directly opened to assist the passengers to leave.

5. If the trapped person cannot leave smoothly when the car is not in the above position, it is necessary to manually level the floor according to the following steps before releasing the passengers.

(1) first calm the passengers' emotions, inform them that the rescue operation is in progress, and (1) let them wait patiently for the rescue.

(2) Remove the protective cover at the end of the elevator traction motor and put the special rotating handwheel on the motor shaft.

(3) Remove the cover of the brake electromagnet and fasten the brake release handle on the brake mechanism.

(4) One person grasps the rotating handwheel, and the other person slowly presses the brake release handle to release the brake mechanism. When the brake mechanism is released, slowly turn the handwheel and use the car to go up or down (clockwise, the car goes up. Turn the car counterclockwise). Stop turning the rotating handwheel and reset the braking device. It must be noted that due to the unbalanced weight of the car, you should be very careful and slow when releasing the brake device manually when turning to prevent excessive acceleration from getting out of control.

(5) Rotating lifting mechanism. When the leveling mark line on the wire rope is aligned with the leveling mark of the elevator, it means that the elevator car has been leveled. At this point, the braking mechanism should be restored.

(6) Open the elevator landing door with the elevator landing door key, and close the landing door after releasing the passengers.

6, by the maintenance unit to conduct a comprehensive inspection of the elevator, eliminate hidden dangers before resuming power supply operation.

Company elevator emergency plan 4 During the elevator license period, passengers are trapped in the car due to elevator failure or power failure, and maintenance personnel and related personnel should carry out emergency rescue. These operating procedures are specially formulated:

1, the rescue of the elevator in the fault state must be carried out by professionals;

2. Rescuers should keep calm and get in touch with the unit and relevant personnel in time to inform the specific situation;

3. The monitoring personnel on duty should explain the cause of the fault to the passengers, make them wait calmly, and discourage them from forcibly ripping off the doors or trying to get in and out of the car, and get in touch with the maintenance personnel;

4. It is forbidden to evacuate trapped people from the safety window in the car to prevent personal injury accidents;

5, determine the unified command, monitoring and operation personnel;

6. Commanders and maintenance personnel should know the number of people trapped and their health status, whether the emergency lights in the car are in good condition, and the parking position of the car so as to carry out rescue operations;

7, before the start of the rescue work, you must first check whether the doors of each floor are closed;

8. Inform the trapped people before the rescue operation that the rescue work will begin, and ask the passengers to cooperate;

9. Remove the protective cover of the shaft head of traction motor in the machine room (if any);

10, according to the elevator manual turning instruction program;

1 1. When the car does not exceed the flat position of the top floor or the bottom floor, the car can move in a labor-saving direction. When the elevator crosses the flat floor of the top floor or the bottom floor, the car should move in the opposite direction to the top floor or the bottom floor;

12. If there is any abnormality during the rescue operation according to the above methods and steps, stop the rescue immediately and call the rescue phone for emergency rescue in time;

13, after the rescue work of fault state, elevator maintenance personnel should comprehensively check the cause of the fault and deal with it in time to restore the normal operation of the elevator;

14, maintenance personnel and related personnel should record the cause of the failure and the troubleshooting methods on the accident record for future reference.

Company elevator emergency plan 5 In order to strengthen the prevention of elevator safety accidents, do a good job in rescue and disposal after safety accidents in time, and minimize losses, the School Elevator Safety Emergency Rescue Plan is formulated according to the requirements of the Law of People's Republic of China (PRC) on Safety in Production and the Regulations on Safety Supervision of Special Equipment. When the elevator breaks down, the elevator administrator immediately informs the person in charge of the unit and the maintenance personnel, and the maintenance personnel or rescuers can try to release the trapped passengers first according to different situations.

(a) Rescue procedures for people trapped in elevators:

1. Rescuers can get in touch with trapped passengers through walkie-talkies or mobile phones.

Be sure to ask passengers to stay calm and wait for rescue. Trapped passengers are not allowed to stick any part of their bodies out of the car. If the door is in a half-open state, rescuers should try to completely close the door to prevent accidents.

2. Accurately judge the position of the car and prepare for rescue. We should judge the position of the car according to the floor indicator light, PC display, floor selector crossbar or door opening, and then try to rescue the passengers.

3, rescue steps:

3. 1 Rescue steps when the car stops near the elevator entrance:

① Turn off the power switch of the machine room;

② Open the outer door with a special lock key;

③ Open the car door slowly by manpower at the top of the car;

(4) assist passengers to leave the carriage;

⑤ Close the hall door again.

3.2 Rescue steps when the car is far away from the elevator:

① Enter the computer room and turn off the fault potential power switch;

(2) Remove the motor tail shaft end cover and press the knob seat and knob;

(3) Rescuers hold the handle hard, and another rescuer holds the brake release lever, gently pry open the brake, and pay attention to the plane sign, so that the car gradually moves closer to the hall door (0.5m);

(4) After confirming that the brake is correct, loosen the turning handwheel, and then rescue according to the method listed in 3. 1.

In case of other complicated situations, please ask the elevator company for help.

5, at the end of the rescue, elevator management personnel must fill in the rescue record and archive, in order to accumulate rescue experience.

(2) Disposal measures in case of fire:

1. When there is a fire on the floor, the elevator manager should immediately try to press the "fire switch" to make the elevator enter the fire-proof operation state; After the elevator runs to the base station, guide the passengers to leave the car quickly, and inform the college leaders by phone, and dial 1 19 at the same time.

2. When there is a fire in the hoistway or car, stop the elevator immediately and guide the passengers to leave. After cutting off the power supply, use dry powder fire extinguisher or 12 1 1 fire extinguisher to extinguish the fire. And call the hospital leaders; If the fire is fierce, you should call the police immediately 1 19 to ensure the safety of people and property in the building.

(3) Treatment measures when the elevator enters the water:

1, when the tunnel is flooded, the elevator should stop above the second floor;

2. When the floor is flooded, stop the elevator on the flooded upper floor, then turn off the main power switch and immediately organize personnel to block the water source. After the water source is blocked, dehumidify it, such as hot air drying.

3. After the technical test, when it reaches the standard, you can try the ladder. After the test ladder is normal, it can be put into normal use.

(4) Emergency treatment of abnormal situations:

When the elevator is abnormal, passengers should be calm and keep a clear head in order to find a safer solution.

(five) in the event of personal injury accidents, in addition to taking necessary emergency measures.

Protect the site, immediately notify the person in charge of the unit and professional maintenance personnel, report to the principal's office, and call "120", "1 10" and "19" for rescue as appropriate.

;