Joke Collection Website - News headlines - What quotas do you need to set for the site shell?

What quotas do you need to set for the site shell?

Quota can't cover all the construction contents on site, and there is no suitable quota like this "site enclosure".

Introduction:

Enclosure and shielding of the periphery of urban construction sites. Play the role of beautification, neatness and unity. Now it will be used for urban infrastructure construction. The height of the enclosure is generally more than 2m, such as 2m, 4m, 6m, 8m, or12m. The enclosure surface, renderings and publicity screen of the project are posted. Or for city public service advertisements.

If the enclosure height is less than 4m, generally single column type is adopted, and the foundation is about 1m deep underground. The diameter of the column is140mm or189mm.

If the enclosure height is more than 4 meters, double columns are generally used, and the foundation of underground deep foundation pit is adjusted with the height. The diameter of the double column is114 mm-219 mm.

The surface is galvanized ceramic tile, generally 0.5mm thick.

Field shell standard:

The construction site must be closed and managed according to the Hygienic Standard for Capacity of Construction Sites in Beijing, and the enclosure height should not be less than1.8m. The shell color should be light blue, gray or white to avoid pollution and paint loss. The enclosure can be painted with light blue, gray or white paint to spray the construction enterprise logo and project name. The setting standard of construction enterprise logo and project name is: "XXX Company undertakes XXX project", the font is imitation of Song Dynasty, the font size is 0.6m×0.8m (width× height), and the lower edge of the font is 0.6-0.8m from the ground. Fonts must be correct, standard, neat and beautiful. The enclosure shall not be used for retaining soil and bearing load, and shall not rely on the enclosure to pile up articles and materials, and shall not be used as a fence to set up temporary sheds, canteens and toilets. The general construction contractor is responsible for the setting and management of the enclosure on the construction site. The construction unit shall be responsible for the enclosure that has not yet been built, and the enclosure management unit shall do a good job in the maintenance and cleaning of the enclosure, keep the enclosure clean and tidy, and shall not arbitrarily post, scribble or depict it. Where slogans and publicity materials are set above the enclosure, they shall be set in accordance with the scope, location, quantity, specifications, content and time limit approved by the municipal administrative department. It is forbidden to use the enclosure on the construction site to set up outdoor advertisements. If the enclosure is not set as required on the construction site, it shall be punished by the municipal and district urban management law enforcement departments according to law; The municipal and district construction committees will order them to make corrections within a time limit or stop work for rectification. If no correction is made within the time limit, it shall be handed over to the municipal and district urban management law enforcement departments for handling.