Responsibility letters usually stipulate the responsibilities of all parties. The responsibility letter is a relatively formal document, which clearly stipulates the rights, obligations and specific terms of both parties. The following is my responsibility book for safe electricity use, and you are welcome to check it.

Responsibility for safe electricity use 1

Party A:

Party B:

In order to ensure the safety of temporary electricity consumption on the construction site and prevent electric shock accidents, this agreement is signed in accordance with the Law of People's Republic of China (PRC) on Work Safety, the Regulations on the Administration of Work Safety in Construction Projects and related regulations. Party A and Party B shall, according to their respective responsibilities, supervise and manage the temporary electricity consumption of the construction project, strictly abide by the rights, responsibilities and obligations agreed in this agreement, and ensure the safety of temporary electricity consumption on the construction site.

I. Rights, Responsibilities and Obligations of Party A

1. Implement the relevant provisions of the state on temporary electricity utilization at the construction site. Responsible for the overall supervision and management of temporary electricity consumption on the construction site, and conduct safety inspection and guidance on temporary electricity consumption on the construction site.

2. Be responsible for providing construction power supply and sending it to the secondary distribution box meeting safety standards (subject to acceptance by both parties). And supervise and inspect the use of Party B. ..

4. When supplying power to Party B, the handover and acceptance formalities shall be handled with Party B. ..

5. Supervise and inspect Party B's temporary electricity equipment and facilities according to relevant temporary electricity consumption standards. If there are hidden dangers in Party B's temporary electricity use, Party B must be instructed to rectify. And supervise the implementation of rectification.

Two. Rights, responsibilities and obligations of Party B

1, strictly implement the relevant national technical specifications and safety operation procedures for electricity consumption, and take overall management responsibility for temporary electricity consumption under the jurisdiction of the construction area.

2. Provide Party A with a written application for temporary electricity use. When equipment and facilities need to increase capacity, they must go through the application procedures for electricity consumption again.

3. When using hand-held power tools, Party B must use safe, reliable and qualified suitcases, and it is forbidden to use other small wooden boards that do not meet the requirements. The power cord must be a multi-strand copper-core rubber-sheathed flexible cable without joint and damage.

4. Wear electric shock protection articles when using electrical equipment; All electrical equipment must be connected with protective wires and plugs, and wires directly plugged into sockets are strictly prohibited.

5. Party B's personnel shall not connect power supply and other unsafe electrical equipment randomly. If electricity is needed, it must be operated by a professional electrician.

Three. Supplementary terms for matters not covered by both parties.

During the on-site construction of Party A, Party B must abide by the on-site labor discipline and obey the safe and civilized construction of Party A.

This agreement is made in duplicate, which will take effect immediately after being signed and sealed by both parties, and each party holds one copy. This agreement shall take effect from the date of signing until the completion of the project.

Party A: Party B:

date month year

Responsibility for safe use of electricity II

In accordance with the provisions of the Electricity Law, the Electricity Supply Regulations, the Power Supply Operation Regulations and other power laws and regulations, in order to better ensure reliable power supply and power grid security, the Company has reached the following agreement:

A, power supply facilities maintenance management responsibility

1. Both power suppliers and users are responsible for the maintenance and management of equipment according to the demarcation point of property rights.

2. Endangering the safety of power grid and electricity consumption, or possibly causing personal injury or equipment damage, or using electricity in violation of the contract, stealing electricity or owing money; The power supplier can change or operate the power supply equipment of power users according to the actual situation.

3. The power metering device and power load management device installed in the power receiving device of power users are maintained and managed by the power supplier, and the power users are responsible for protecting and monitoring their normal operation; If there is any abnormality, the power user shall notify the power supplier in time.

Second, the responsibility of safe operation management

1. The power supplier shall continue to provide qualified power supply to the power users in accordance with the provisions of the power supply contract between the two parties.

2. The electrical personnel on duty of power users must be familiar with the relevant provisions of the safe electricity technology operating rules, electricity system, equipment dispatching authority division and operation mode, and must formulate and strictly implement the on-site switching operating rules. Power users appoint full-time electricians to represent Party B's behavior. Full-time electricians must hold high-voltage network access certificates, and unlicensed electricians are strictly prohibited from conducting electrical operations. In case of safety accident, all consequences shall be borne by the responsible unit.

3. The power user must submit the list of personnel on duty for power transformation and distribution to the power supply inspection department; If there is any change in the personnel on duty, it must notify the dispatching department and the electricity inspection department of the power supplier in writing.

4. Without the consent of the power inspector of the power supplier, the power supplier shall not change the primary and secondary wiring of the self-provided generator and power supply system, and shall not supply power to other users.

5. Users must provide necessary and qualified protective articles for safe electricity use for construction personnel.

6. Full-time electricians of power users must cooperate with Party A in the maintenance and inspection of power system, and shall not shirk.

Three. Agreed matters and liability for breach of contract

1. The power supplier puts forward written rectification opinions on the potential safety hazards of power users; After the rectification, the power users should make timely acceptance. The power supplier does not assume any responsibility caused by the unqualified electrical equipment of users.

2. If the power user fails to perform the maintenance and inspection obligations in accordance with the agreement, resulting in the self-provided power supply equipment (including protection facilities) running with diseases and potential safety hazards, the power supplier has the right to directly stop supplying power to the power user.

4. All consequences of unsafe operation of power grid due to misoperation or equipment defects shall be borne by users.

5. If the user fails to implement this agreement or relevant regulations, and the management is not in place, causing personal and equipment damage to the power supplier or society, the user must bear all the responsibilities.

6. The power supply bureau will not be responsible for any accident on the user's property line.

7. The power supplier shall determine the meter reading date and charge the meter reading on time. The electricity user shall pay the electricity fee within the time limit specified by Party A. Those who fail to pay within the time limit will be charged a late fee according to the regulations, and the power supply can be stopped.

Four. Validity and matters not covered in this agreement.

1. Matters not covered in this agreement shall be handled in accordance with the provisions of relevant laws and regulations such as the Electricity Law, Regulations on Power Supply and Utilization, and Rules on Power Supply Business; In case of adjustment of national laws and policies, relevant clauses of this contract shall be revised and supplemented according to corresponding regulations.

2. The validity period of this agreement is from 20__ _ _ 10/day to 20__ _ 1 0/day. After the expiration of the agreement, if neither the power supplier nor the power supplier proposes to change or terminate the agreement, the agreement will remain valid.

3. This agreement shall come into effect after the power supplier and the power user sign and affix their official seals.

4. The original of this agreement is in duplicate. The power supplier and the power user each hold one copy.

Power supplier: (signature) Power user: (signature) Address:

Tel: Tel:

Signing time: Year Month Date Signing time: Year Month Date

Responsibility for safe use of electricity 3

In order to strengthen the school electricity safety work, enhance teachers' awareness of electricity safety, ensure the safety of school property and teachers' and students' lives, and ensure the smooth progress of school education and teaching, according to the relevant requirements of the District Education Bureau for safety work, the responsibility book for electricity safety in Limin No.1 Middle School is formulated:

1, complete all kinds of electricity work in strict accordance with the electricity safety regulations, and do not install and connect wires without permission.

2, the office power supply and electrical appliances to make sure that the person in charge, that is, on and off, when not in use, especially after school, holiday, but also to special inspection, to ensure foolproof.

3, without the approval of the school, no one may change the line, not disorderly pull. The school will investigate the responsibility of the parties and give financial penalties to those who install or tamper with it without permission.

4. Use electricity in strict accordance with the electricity regulations. Who is in charge, who is responsible, who uses electricity, who is responsible? In the event of a safety accident, the parties concerned will be held fully responsible.

School signature (seal)

Responsibility for safe use of electricity Article 4

Recently, there have been several fire accidents caused by unsafe electricity use in the county, which have caused great losses. These accidents have aroused people's vigilance against the safe use of electricity. In order to prevent the accident from happening again and ensure the property safety of the company's stores, the group company decided to implement the target responsibility system for the electricity safety of the stores, and the company signed relevant responsibility letters with the store leaders.

First, the target responsibility should be implemented to people. The signatory is the first responsible person for electricity safety, and is mainly responsible for electricity safety.

Second, strengthen the management of store equipment and electricity consumption. Always check the use of power supply equipment, and contact an electrician to solve the problem if found. In case of special circumstances, you should immediately cut off the power supply and contact an electrician. Problems should be solved in time without delay.

Third, carefully check the electricity consumption in the store. If it is found that there is a plug or illegal electrical appliances are used, it should be corrected in time to avoid accidents.

Fourth, do a good job in safety precautions to save electricity, turn off unnecessary lighting equipment in time, let people turn off the lights at will, and allocate electricity reasonably without causing accidental waste.

Five, without the approval of the company, no one is allowed to change the line at will and connect the circuit randomly.

6. The person in charge of the store will be responsible for the equipment damage and personal and property losses caused by changing the power cord, illegally operating the equipment and using high-power electrical appliances, and the company will not bear any responsibility.

Administration Department (signature): regional person in charge (signature):

Store Manager: _ _ _ _ _ _ _ _ _ _ _ _

Responsibility for safe use of electricity Chapter V

In order to strengthen the management of power consumption in sub-bureaus and prevent the occurrence of power consumption accidents in maintenance stations, this responsibility book for safe power consumption is specially formulated.

First, consciously accept the management of safe electricity use, and strengthen the implementation of safe electricity use management when using electrical appliances; It is necessary to take full responsibility for the safe use of electricity, arrange special personnel to manage it, and formulate relevant measures to ensure the safety of electricity use;

Second, there should be a special person to check the safe use of electricity before work every day, so as to cut off water, power, close windows and lock doors; All kinds of electrical equipment and instruments must be kept in normal operation, and overload and sick operation are strictly prohibited.

Three, repair electrical equipment, instruments, should be operated by electricians or professionals and carefully check. The indoor circuit is not allowed to be changed. Changes due to work needs must be approved by the unit department. Without the permission of the unit department, high-power electrical appliances are not allowed to be used, and the power cord is not allowed to be pulled privately to prevent fire;

Four, renovation, involving the change of the original electricity, water lines and pipelines or newly installed lines, should apply to the power supply department in advance, and provide the renovation and renovation of the line layout, so as to facilitate future inspection and maintenance;

Five, where an accident occurs in violation of the provisions, the person in charge of the accident maintenance station or the perpetrator shall bear all criminal responsibility and economic losses.

Xinhe highway sub-bureau safe production leading team

Maintain webmaster's signature:

Power user signature:

Responsibility for safe use of electricity 6

In order to ensure the safety of temporary electricity consumption in site construction, according to Technical Specification for Safety of Temporary Electricity Consumption in Construction Site (JGJ46-88), each construction team must have a certified electrician to take up their posts and strengthen the management of construction electricity consumption; However, in view of the fact that the electrician's license of each construction group of my project is still being processed, I hereby sign this responsibility letter for each construction group, hoping that each construction group must use electricity according to the following requirements.

Construction personnel are strictly forbidden to walk on the herringbone ladder, and the consequences will be borne by the construction personnel. If it is found, it will take photos to collect evidence. 100 yuan/person? Time.

(1) The electricians at the site of the construction ZuoYeDui must master the basic knowledge of temporary electricity utilization and the standard erection of facilities and lines; And comply with the temporary electricity safety disclosure.

(2) Electricians shall be equipped with protective articles for safe operation, which shall be used as required during operation; Otherwise, the project department will purchase the goods and charge 20% of the cost.

(3) The distribution box is locked and managed by professionals; There should also be rain-proof and anti-corrosion measures, and sundries should not be piled up around; (4) The distribution box and switch box should be installed correctly and firmly. The movable distribution box and switch box should be installed on a solid bracket. The vertical distance between the bottom of the fixed distribution box and switch box and the ground should be greater than 1.3m and less than1.5m. ..

5. Every electrical equipment must be implemented ("one machine, one brake and one leakage" system, and it is strictly forbidden to directly control more than two electrical equipment including sockets on the same switch).

[6], distribution box, switch box wire import and export should be located in the bottom of the box, it is strictly prohibited to set at the top of the box, side, back and door. Incoming and outgoing lines shall be bound with sheaths and made waterproof bends.

A, all distribution box, switch box maintenance once a week, completed by a full-time electrician. When working, you must wear insulating shoes, gloves and insulating tools as required.

Being the head of the construction team must be in strict accordance with the requirements of the responsibility book. If there is a safety accident due to illegal temporary electricity use, the corresponding head of the construction team will take full responsibility for the economic losses, and the project department will impose a fine of 1000 yuan according to the accident circumstances.

Unit: