How many precautions are there in computer room construction?
First of all, we should design and plan according to relevant standards and technical specifications, and select and install equipment according to specific requirements. Secondly, we should try our best to create a reasonable working environment under the conditions of lighting, dust prevention and sound insulation. Among them, it should be considered that the ceiling and wall decoration materials and frames should meet the fire protection requirements, use flame retardant decoration materials, and coat the surface with flame retardant coatings to meet the requirements of flame retardant and arson prevention. The anti-static floor with wear-resistant and anti-static finish is the first choice for the computer room floor, which has good anti-static performance and will not deform or fade after long-term use; The floor clearance height is usually 10- 1250 px. Indoor lighting, air conditioning and humidity equipment should be considered comprehensively: double-layer alloy glass windows should be installed for sound insulation and dust prevention, with shading curtains, etc. Height and space of computer room: The height and space of computer room should consider the clear height after floor laying and ceiling decoration. As the machine room mostly adopts down-feed mode, trunking and ventilation should be laid under the floor, and the clear height of the floor is generally around 10- 1250 px; Generally, the ceiling of the roof should reach the lower part of the beam, and the buried height of lamps and fire fighting equipment should be sufficient, which usually occupies a certain height, so the clear height of the room is reduced by nearly 1m, and the height of ordinary buildings will be lower after the transformation of the computer room, which is not conducive to the installation of equipment. The clear height of the building should be within the range of 3.2m~3.3m (wiring racks or passages should be set in the machine room). At present, there should be air supply pipes under the floor of large computer rooms. Therefore, computer room buildings or specific floors and computer rooms should be designed as a whole when designing building facilities. For the central computer room, with the development of new technology and new equipment, the business will continue to expand, and some equipment space should be reserved appropriately according to the medium and long-term development trend. The equipment in the computer room is generally installed according to the principle of isolation between the cabinet and the operation room.
- Related articles
- 6-character gas safety slogan
- Can the account management fee 10 yuan of CCB be cancelled?
- How many generals did Hubei Dawu produce?
- Take care of flowers and plants slogan Primary school students grade three
- Girlfriend jokes
- How many people need to report for the meeting, and which law stipulates it?
- School Office Brand Slogan
- Which is better, Shunfeng City or Flash?
- When the new pneumonia broke out, many people suffered psychological trauma. What are the manifestations of psychological trauma?
- Help me revise an article (news)