How to use and adjust electronic weighbridge.
The use of electronic weighbridge is relatively simple. First of all, you should be familiar with the basic functions of cleaning, peeling, peeling and printing on the instrument. Don't pound the weighbridge when weighing things. Place the items in the middle of the weighing platform as much as possible. Wait until the object is stable for 3-5 seconds and then read the exact weight. Clean up the garbage under the weighbridge every month or several months to keep the weighbridge in a dry environment.
So how to debug the electronic weighbridge if it is not accurate?
It depends on your instrument model. Instruments used in small electronic weighbridge include A6 A 12+e A9, etc.
A6 calibration method is as follows:
Step operation display comments
Press [D00 1] and use the 1 reset key to enter the calibration state.
2 press the peeling key to select the scale value, and press the zero key to confirm the scale value set in [d 1]: (press the peeling key to step and cycle) 1, 2,5,10,20,50,100,200, and step and cycle without modification. For example: 2
3 Press the peeling key to select the decimal point, and press the return to zero key to confirm that 【 d P 2 】 sets the decimal point position: (press the peeling key to step and cycle) 0, 1, 2, 3, 4, step and cycle, corresponding to 0~4 digits respectively; For example: 2 (Note: setting the decimal point plus 5 can prohibit the instrument from entering the power saving mode)
4 Set the input full scale with the function accumulation skinning key. Press the zero key to confirm that 【 F030.00 】 is set to full scale: press the accumulation key to change the blinking position circularly to the right, press the function key to change the blinking position circularly to the left, and press the skinning key to automatically increase the blinking position 1. Bit-by-bit input full scale, the same below. Press the zero key to confirm and proceed to the next step. For example 3000
5 After it is stable, press the zero key to confirm 【 noLoAd 】 zero calibration: make the instrument in an empty scale connection state. After the stable indicator light is on, press the zero key to confirm the zero point, and the instrument will display "-"for about two seconds before entering the loading calibration.
6 Input the actual weight of the weight on the weighing platform through the function accumulation stripping key, and press the return-to-zero key to confirm the linear calibration of 【 ad load】【a 030.00 】: load a certain load (the closer it is to the full scale, the better). Input the actual weight of the weight loaded on the weighing platform (for example, 3000), and the input method is the same as step 4. After the stability indicator lights up, press the zero key to confirm, the instrument will display "-",and then go to the next step.
7 Return to working state after calibration [* * * *] Instrument calibration is over. Note: During the calibration process, press the reset key to interrupt the calibration and return to the working state.
The calibration method of A 12+e is as follows:
1. Press the # key to enter the calibration state during initialization.
1. Setting of dividing value:
Display d× press the stripping key to select 1, 2,5,10,20,50, press the # key to confirm and enter automatically.
Parameter setting. Press the peel key to automatically display the step cycle.
Show dX
Display d 1
Display d2
Display d5
Display d 10
Display d20
Display d50
Display d 1
For example, when d5 is displayed, press the # key, the frequency division value will be set to 5, and the decimal point will be set automatically.
2. Decimal point setting:
Display P× Press the Peel key to select 0, L, 2 and 3, and press the # key to confirm, and the next parameter setting will be automatically entered.
Press the peel key to automatically display the step cycle.
Display P0
Display P0.0
Display P0.00
Display P0.000
Display P0
For example, when P0.000 is displayed, press the # key, the decimal point will be set to 0.000, and the maximum weighing setting state will be automatically entered.
3. Maximum weighing setting:
Display full press the peeling key to enter the digital input state.
When 000000 is displayed, press the peel key, and the symbol V moves to the right in turn. Select the calibration method input position of digital weighing platform A 12A 12E, and press the zero key pair.
It should be automatically added step by step until the required number appears, then press the stripping key identifier V to move to the right in turn to select the number input position, press the zero key to automatically add step by step until the maximum scale value appears, and press the # key to confirm and automatically enter the next parameter setting.
For example, if 025000 is displayed, press the # key to confirm and automatically enter the zero calibration state.
4. Zero calibration:
There is nothing on the no-load scale, wait for the stable mark V to appear, and then press the # key to complete the zero calibration.
Enter the range calibration state.
5. Full-scale calibration:
Display AdLOAD to place a weight on the scale, and press the peeling key to enter the input state.
When 000000 is displayed, press the peel key, and the symbol 1-r moves to the right in turn to select the digital input position, and then press zero.
The corresponding position of the key will automatically increase by one step by step until the required number appears, then press the peel key mark V to move to the right in turn to select the number input position, and press the zero key to automatically increase by one step by step until the displayed number and weight are equal, and return the input position mark to the highest position. When the stability mark V appears, press the # key to confirm and end the range calibration state.
Show ending
6. Press the SPAN key to save the parameters and return to the weighing state.
2. Press the # key to enter the calibration state during initialization.
1. Fast zero calibration:
Any time before. . Display nOLOAD, press the function key to keep the original graduation value, decimal point and maximum weighing parameter settings unchanged, and the instrument will directly enter the zero calibration state. Wait until the stable identifier V appears, press the zero key, and the display of End means to keep the original full-scale calibration parameters, then press the SPAN key to save the parameters and return to the weighing state.
2. Directly enter the full-scale calibration state:
At any time before AdLOAd is displayed, press the accumulation key, and keep the original setting of graduation value, decimal point and maximum weighing parameters unchanged, and keep the original zero parameter unchanged, and directly enter the full-scale calibration state.
- Previous article:Passers-by don't have to go backwards (selected 46 sentences)
- Next article:Summary of teaching work
- Related articles
- Summary of the work of the trade union in the first half of the year
- How to solve the parking problem in the city?
- Excellent slogans about protecting green environmental protection?
- What do you mean by child care fee?
- Slogan of senior three one
- 2022 Wuhan National Day Flower Expo Tour Guide XI Wuhan Flower Expo Tour Guide
- Inspirational sentences about the sales of gold, nine silvers and ten silvers
- Prompt slogan button
- Garbage creative classification banner slogan
- Steel industry slogans