Siemens PLC controls the use of running water lamp. Who can do that?

It is very convenient to control the running water lamp with "timing program controller". Timing time can be set at will, and timing and program operation can be realized through setting, without programming.

Precision control-timing program controller is used as timing and program control in automatic control of equipment. On the basis of timing control, program control functions with different functions are realized through setting. The biggest feature is: no programming, simple and easy to use, table setting replaces traditional programming, which greatly reduces the difficulty in the application process and is very suitable for people who are not familiar with programming.

TPC8-8TD is a basic timing program controller, which can set 60 lines of functional data, and each line of functional data is a multi-line working program. You can set each line of working programs to work independently, or you can start or stop the work of other lines of programs after executing this line of programs.

Each working program has a delay timer and a working timer, and different delay timing and working timing can be set respectively. The two timers work alternately, and the delay timer is used as the delay after the program of this bank is started, and then it becomes the working timer after the delay. The two timers can be set to work in cycles, the number of cycles can be 1-65535 times, or they can be set to infinite cycles, thus realizing the timing control of intermittent output at different intervals. The setting of the timing time is flexible. As long as the interval is 50 milliseconds, it can be set arbitrarily in the range of 50 milliseconds to 24 hours.

The basic timing program controller has eight input channels, which are used as input control terminals for starting and stopping single-line programs or multi-thread sequences, and can be directly connected with switch signals such as switches, contacts, switch sensors and logic level changes as input control. Different or identical input terminals can be set as control terminals for each line of programs, and each input terminal can be used independently or repeatedly in multi-line programs.

The basic timing program controller has eight output channels, and each output channel is an output end, which can directly drive and control loads such as solenoid valves and relays. Each line of program can choose to set any output terminal as the output terminal controlled by this line of program, and each output terminal is allowed to be used independently in the program line or reused in the multi-line program.

Timing program controller adopts photoelectric and electromagnetic multiple isolation technology, which has high reliability and strong anti-interference ability and is an ideal control device for equipment timing program control.