Joke Collection Website - Bulletin headlines - Environmental protection slogan of landfill leachate

Environmental protection slogan of landfill leachate

Pollutant emission control requires that domestic waste landfill sites should be equipped with sewage treatment devices, and domestic waste leachate and other sewage (including regulating tank wastewater) can be directly discharged after being treated and reaching the pollutant emission control requirements specified in this standard.

The existing and newly-built domestic waste landfill sites shall, from +0: 00 on July 6, 2008, implement the emission concentration limit of water pollutants as specified in Table 2. According to the requirements of environmental protection, methane emissions should be strictly controlled in areas where the land development density is already high, the environmental carrying capacity is beginning to weaken or the environmental capacity is small, the ecological environment is fragile, serious environmental pollution problems are prone to occur and special protection measures need to be taken. It is required that the volume percentage of methane in the height range below 2m of the landfill surface shall not be greater than 0. 1%. Methane emission reduction measures should be taken in domestic waste landfill; When landfill gas is directly discharged through the airway, the volume percentage of methane at the outlet of the airway is not more than 5%, and necessary measures should be taken to prevent the diffusion of malodorous substances during the operation of domestic waste landfill. The concentration of malodorous pollutants at the boundary of environmental sensitive points around the domestic waste landfill should meet the requirements of GB 14554.

In any case, the domestic waste landfill should comply with the pollutant emission control requirements of this standard, and take necessary measures to ensure the normal operation of pollution prevention facilities. Domestic waste landfill should be equipped with sewage treatment device, and domestic waste leachate (including wastewater from regulating tank) and other sewage can be directly discharged after being treated to meet the pollutant discharge control requirements specified in this standard. The existing and newly-built domestic waste landfill sites shall, from +0: 00 on July 6, 2008, implement the emission concentration limit of water pollutants as specified in Table 2. According to the requirements of environmental protection, in areas where the land development density is already high, the environmental carrying capacity is beginning to weaken, or the environmental capacity is small, the ecological environment is fragile, serious environmental pollution problems are prone to occur and special protection measures need to be taken, the pollutant discharge behavior of domestic waste landfills should be strictly controlled, and the special discharge limit of water pollutants specified in Table 3 should be implemented for existing and newly built domestic waste landfills in the above areas from July 1 2008.