Joke Collection Website - News headlines - Will stealing electricity affect the leakage switch?

Will stealing electricity affect the leakage switch?

measures to prevent electricity theft of single-phase meters

in order to improve safety production and economic benefits and protect their own interests, the administrators of the station area need to conduct a comprehensive and thorough verification and cleaning of all users' meters and lines in the whole area at regular intervals. After the meter is calibrated, the following points should be paid attention to during installation:

1. Try to unify the colors of wires when installing the meter, and connect wires with different colors to different phase wires. And absolutely ensure that the terminal 1 of the electric meter is the live wire and the terminal 3 is the zero wire. After the incoming line is installed, in order to prevent some users from secretly disconnecting the main zero line for private grounding, electroprobe is used to measure whether there is induced electricity at the 3 rd and 4 th ends of the incoming line. If there is no indication that the line is normal, if there is, the main line to the meter may have been disconnected. It is necessary to find out the location of the broken point immediately and analyze whether it is artificially disconnected according to the broken point. If it is artificially disconnected, the user will be listed as the key inventory object. If everything is all right, connect the terminal of the electric meter. After the wires are connected, turn all the screws of the terminal and the connecting screws of the electric meter again. And make sure it is firmly connected.

second, cover the cover plate of the electric meter terminal and seal it with lead. When sealing with lead, tie a knot after threading the lead sealing line and shorten the lead sealing line as much as possible. Move the lead sealing block to the knot and seal with lead. Choose a thin paper seal, write the user's name and paste it.

third, check whether the user leakage protector can normally disconnect the power supply, and if it is damaged, it must be replaced immediately. If it is normal, use electroprobe to measure whether the two terminals of the outgoing line are one zero one fire. Disconnect the power supply and connect the line to the user's home, and close the switch to see if the power consumption is normal. If the leakage protector can't be closed, it means that there is a problem with the line in the user's home, and the user's line should be checked. Don't not install it because you are afraid of trouble, or there may be two results, and these two reasons will lead to the failure of the general protection in the Taiwan area:

(1) The user has privately set up a ground wire to steal electricity.

(2) The line in the user's home is out of order, which may lead to safety accidents.

4. For the platform area where no leakage protector is installed, you should bring your own leakage protector to check the subscriber line.

5. Check the meter box to see if it is in good condition or defective. If it is not sealed with lead. When sealing with lead, tie a knot after threading the lead sealing line and shorten the lead sealing line as much as possible. Move the lead sealing block to the knot and seal with lead. Choose a thin paper seal, write the user's name, the number of the station location and the propaganda slogan of electricity use, and then paste it. And publicize some basic common sense of electricity use to users.

six, after the meter is cleaned, it will be the monthly patrol work. As a district manager, you didn't just collect the electricity bill to complete the task. It is most important to manage the station area well, improve line loss and ensure safety. Take time to go around the Taiwan area, especially when the phenomenon of linking with drought resistance is serious at night. Try to make more noise in the jurisdiction, let users know that you are not only in the jurisdiction during the period of meter reading and charging, so that thieves dare not steal electricity blatantly.

7. When reading the meter every month, check whether the lead seal and paper seal of the meter below are damaged. Is there anything on the main line that shouldn't appear? It's best if we can form a mutual aid group together with several administrators in the Taiwan area to check the lines and deal with the power thieves. This is safe, and it can give the thief a shock. Try to catch a thief in each district and hand him over to the judicial department to make an example of him. And a few people joined forces to cut green and sweep obstacles in various districts and clean porcelain bottles on poles.