Article 89 When anyone discovers an underground fire, he shall, according to the nature of the fire, the ventilation and gas situation in the disaster area, immediately take all possible methods to put out the fire directly, control the fire, and report to the mine dispatching room quickly. After receiving the underground fire report, the mine dispatching room shall immediately notify the relevant personnel to organize the rescue of the people in the disaster area, and implement the fire fighting work according to the disaster prevention and treatment plan.
The mine dispatcher on duty and the district, team and team leader at the scene shall evacuate all personnel in the area that may be threatened by fire and organize personnel to put out the fire according to the provisions of the disaster prevention and treatment plan. When the electrical equipment is on fire, the power supply should be cut off first; Before cutting off the power supply, non-conductive fire extinguishing equipment must be used to extinguish the fire.
In the process of rescue and fire fighting, it is necessary to designate a special person to check the changes of concentration, wind direction and air volume of harmful gases such as methane, carbon monoxide and coal dust, and take safety measures to prevent gas and coal dust explosion and personnel poisoning.
Article 93 When dealing with external mine fires in different places, the following provisions shall be met:
First of all, when dealing with fires on the mountain and under the mountain, measures must be taken to prevent airflow reversal caused by fire wind pressure and airflow blockage caused by roadway collapse.
Second, the whole mine should be ventilated when dealing with the fire in the wellhead, shaft, bottom, main air inlet roadway and air inlet shaft chamber. Before going against the wind, people on the windward side of the fire source must be evacuated and measures should be taken to prevent the fire from spreading.
When several main ventilators jointly ventilate the mine, it is necessary to ensure that the main ventilators in the non-accident area are against the wind first, and the main ventilators in the accident area are against the wind later. When taking short-circuit measures, all personnel in the affected area must be evacuated.
Three, when dealing with the fire in tunneling faces, the original ventilation state should be maintained, and measures should be taken after reconnaissance.
Four, when dealing with explosives warehouse fire, the detonator should be shipped out first, and then other explosives will be shipped out; If it cannot be transported out due to high temperature or explosion danger, close the fire door and evacuate the place.
Five, when dealing with the winch room fire, should be fixed at the bottom of the fire, to prevent the burning wire rope sports car cuts.
Six, when dealing with battery motor garage fire, should cut off the power supply and take measures to prevent hydrogen explosion.
- Related articles
- Slogans for celebrations of March 8th
- What color is the company's unqualified flag?
- Planning book of environmental protection creative competition
- Model essay on summary report of community activities
- How about Guilin Tourism College? What is the surrounding environment like?
- Details of the ten main forces and weapons and equipment of the Kuomintang.
- Summary of community legal publicity activities
- It is prohibited to use illegal electrical appliance slogans
- Arbor Day slogans
- The girl in Hangzhou found her car missing after work. What happened?