Joke Collection Website - Bulletin headlines - What is the general height of the factory building?

What is the general height of the factory building?

The standard height of industrial workshop is: generally 5 ~ 6 meters lower and 30 ~ 40 meters higher. The starting height of a high-rise factory building is 24m or even higher.

The width (span), length and height of a single-storey factory building are determined according to the technological requirements on the basis of meeting certain building module requirements. The standard spans of industrial workshops are: 6, 9, 12, 15, 18, 2 1, 24, 27, 30, 36m, etc. The standard length of an industrial workshop is from tens of meters to hundreds of meters. On the basis of technical economy and rationality, the shape of the workshop should be as simple as possible to avoid setting height difference in vertical and horizontal spans and multi-span workshops.

Extended data:

Code for design of standard workshop:

1, industrial plant design must implement the relevant national policies, so as to be technologically advanced, economical and reasonable, safe and applicable, ensure quality, and meet the requirements of energy conservation and environmental protection.

2. This specification is applicable to the design of newly built, rebuilt and expanded industrial workshops, but it is not applicable to biological clean rooms with bacteria as the control object. The provisions on fire prevention, evacuation and fire fighting facilities in this specification are not applicable to the design of high-rise industrial workshops and underground industrial workshops with a building height exceeding 24 meters.

3. When the original building is used for clean technical transformation, the design of industrial workshop must be based on the requirements of production technology, suit measures to local conditions and treat it differently, and make full use of existing technical facilities.

4. The design of industrial workshop should create necessary conditions for construction, installation, maintenance and management, testing and safe operation.

5. The design of industrial workshop should not only be implemented according to this specification, but also meet the relevant requirements of current national standards and specifications.

6. The industrial workshop consists of independent buildings (workshops) and independent buildings (dormitories). The distance between the two buildings is10m, and shall not be less than 5m recently, so as to eliminate acceptance. The ratio of building area to building area is 1: 3.

Baidu encyclopedia-factory building

Baidu encyclopedia-industrial workshop