Joke Collection Website - Bulletin headlines - The validity period of sterilized aseptic packaging is

The validity period of sterilized aseptic packaging is

The time is 7 days, the shelf life of aseptic packaging is 7 days, and there is no pollution. If it expires or gets wet, it should be disinfected again. Sterile articles should not be exposed to air, but should be stored in sterile bags or containers. The name and sterilization date of the article should be marked outside the sterile bag, and discharged in the order of validity.

If the contents of the bag are not used up at one time, wrap it according to the original crease and indicate the opening time, which is valid at 24: 00. If the contents of the bag are accidentally contaminated or soaked, it needs to be disinfected again. When you take all the things in the small bag, you can open it in your hand. Untie the tie knot, hold the sterile bag with one hand, turn the four corners of the bag into the palm of the bag with the other hand, accurately put the contents of the bag into the sterile container and cover it.

Extended data:

Sterile goods management:

1. Strengthen the monitoring of washing quality of syringes, needles and other articles, and conduct routine glucose tolerance measurement, heat source measurement and bacterial monitoring once a month. Measure the transparency and PH value twice a week.

2, all kinds of disinfection logo is clear and complete, must have a name, effective date, person in charge, check. Unclear identification and incomplete records shall not be issued. Each package should be affixed with adhesive tape and sterilization indicator tube, and sterilized with 132℃ pressure steam to determine the sterilization effect. If it does not meet the requirements, it should be sterilized again.

3. Strengthen the management of disinfection. The sterilizer should strictly implement the high-pressure sterilization procedure to ensure the disinfection effect, check and record the sterilization temperature, pressure, time and indicator display results in time, and keep them for 7 days according to the regulations, and conduct a 13-0 test every morning before each pre-vacuum pressure cooker is sterilized. The supply room shall be supervised and inspected by the quality supervisor at any time.

4. In order to ensure the sterilization result of autoclave, thermophilic acidophilic lipase is used as indicator bacteria once every quarter to determine the thermal sterilization effect.

5. Sterilized sterile articles should be kept clean, dry and pollution-free during transportation. Vehicles in the disinfection room (divided into sterile vehicles and clean vehicles) should be wiped with disinfectant every day and marked.

Baidu encyclopedia-disinfection supply center

Baidu encyclopedia-aseptic packaging