Joke Collection Website - Blessing messages - Fire safety drill plan

Fire safety drill plan

Example 1 of the plan: A fire broke out in an office on the 7th to 14th floors of the comprehensive building during working hours

1. In the early stage of the fire, the person in charge of the office directed the scene and quickly conveyed information while calling for help. Organize efforts to put out the initial fire. At the same time, report to the fire monitoring center (telephone: ) and the fire protection person in charge of the floor. If the fire is large or spreads rapidly, you can directly call 119 to call the Yangzhou Public Security Fire Brigade.

2. After the fire monitoring center receives the report or the fire monitoring center alarm system receives the fire alarm signal, it quickly cuts off the power supply of the floor and the upper and lower floors, turns off the fresh air blower, and starts the smoke prevention and exhaust fan and positive pressure The air blower, fire pump, and sprinkler pump are started. At the same time, one person (position 1) quickly goes to the scene to inspect, and the other person (position 2) stays in the duty room to be responsible for external contact and operating equipment. Based on the fire scene conditions, it is decided whether to make an emergency landing of the passenger elevator and start the fire protection. Elevators, close fire rolling shutter doors, etc.

3. The left-behind duty officer (position 2) of the fire control center quickly notified the electrical on-duty staff in the office area (telephone: ), the on-duty police officer (telephone), the BAS (building automation control) on-duty staff, and department leaders, At the same time, it is decided whether to call the fire alarm 119 based on the fire development reported at the fire scene.

4. Department leaders rushed to the scene quickly and notified the fire safety leader of the bureau.

5. When the fire monitoring center cannot cut off the electrical equipment on the fire floor and related floors, the BAS (Building Automation Control) monitoring room will be responsible for cutting off.

6. The electrical personnel on duty should ensure the normal power supply of fire protection equipment (fire pumps, sprinkler pumps, etc.), and the fire floor and related floors cannot be cut off in the fire monitoring center and BAS (Building Automation Control) monitoring room. When the power supply and electrical equipment are switched off, the electrical personnel on duty shall manually cut off the power supply.

7. The on-duty police officers quickly opened the two side doors. The on-duty police officers who arrived were responsible for maintaining order at the fire scene and preventing crowd congestion. At the same time, there were police officers downstairs who were responsible for clearing roadblocks and guiding fire trucks to enter. corresponding location.

8. Volunteer firefighters from each floor rushed to the fire scene, and fire leaders from the office area rushed to the fire scene. The fire leaders from the office area served as the on-site commander and commanded the fire extinguishing. Depending on the size and development of the fire, they decided to take measures What kind of fire-fighting plan will be used will also determine whether on-site personnel and important materials and equipment should be evacuated.

9. The fire control room switches the broadcast to fire broadcast and promptly conveys the command headquarters’ notice.

10. The medical emergency team shall be prepared to rescue the injured and contact the local emergency center as appropriate.

11. Volunteer firefighters from other departments must obey the unified command of the headquarters after arriving at the fire scene.

12. After the fire trucks and fire-fighting troops arrive, the fire brigade leader will serve as on-site command.

13. After the fire is extinguished, leave someone to check the remaining fire to ensure that no remaining fire or hidden dangers remain.

14. After the fire is extinguished, the Public Security Department and Safety Department will cooperate with the fire brigade to protect the fire scene.

15. The fire-generating unit, the Public Security Department, the Safety Department and the Yangtze Management Center shall cooperate with the public security fire brigade to investigate the cause of the fire.

Notes:

1. All employees in the office area must be familiar with the terrain structure, surrounding environment, etc. of the office area.

2. All employees, especially volunteer firefighters, must be familiar with and master the configuration, storage location and use of fire-fighting equipment.

3. Commanders at all levels and relevant departments must be familiar with their work responsibilities, ensure that they can be in place quickly and promptly after a fire occurs, and skillfully perform and complete fire-fighting tasks.

4. During the evacuation and evacuation of people, the passenger elevators will be stopped and all people will be evacuated from the safe passage. The fire elevators will only be used by fire fighters.