What does wired ZCKVV mean? What does ZC mean?
ZCKVV is a kind of flame retardant control cable.
reference data
Difference between specifications and models of cables and wires and commonly used wires
The wire is composed of one or more flexible wires, and the outer bread is covered with a light and soft protective layer; A cable consists of one or several insulated wires covered with a tough outer layer made of metal or rubber.
Cables generally have more than two insulation layers, most of which are multi-core structures, and are wound on cable reels, and the length is generally greater than 100 meters. Wires are generally single-layer insulated, single-core, 100 meter coil and wireless disk.
Cable wires are generally composed of core wire, insulating sheath and protective sheath.
BV-Copper Core PVC Insulated Cable (Wire)
Copper conductor PVC insulated flexible cable (wire)
BVV copper core PVC insulated PVC sheathed round cable (wire)
BVVB-Copper Core PVC Insulated PVC Sheathed Flat Cable (Wire)
BV- 105- Copper Core Heat Resistant 105 Degrees PVC Insulated Wire
BV-ZR copper core flame retardant PVC insulated wire
BVR-ZR copper core flame retardant PVC insulated flexible wire
BVV zirconium copper core flame retardant PVC insulated PVC sheathed round cable
BVVB-ZR copper core flame retardant PVC insulated PVC sheathed flat cable
BV-ZR- 105 Copper Core Heat Resistant 105℃ Flame Retardant PVC Insulated Wire
BVR-ZR- 105 Copper Core Heat Resistant 105℃ Flame Retardant PVC Insulated PVC Sheathed Round Flexible Cable
BVV-ZR- 105 Copper Core Heat Resistant 105℃ Flame Retardant PVC Sheathed Round Cable
AV-ZR- 105 Copper Core Heat Resistant 105℃ Flame Retardant PVC Insulated Installation Wire
AVR-ZR- 105 Copper Core Heat Resistant 105℃ Flame Retardant PVC Insulated Flexible Wire Installation
AV-ZR copper core flame retardant PVC insulated installation wire AV-ZR copper core flame retardant PVC insulated installation flexible wire
RVB-Copper Core PVC Insulated Flat Connecting Cord
RVS-Copper Core PVC Insulated Stranded Connecting Cord
RVV copper core PVC insulated PVC sheathed flat connection flexible cable (wire)
RV- 105- Copper Core Heat Resistant 105 Degrees PVC Insulated Connecting Cord
SYV: Solid polyethylene insulated RF coaxial cable
SYWV (Y): Physical foamed polyethylene insulated cable for CATV system, and video (RF) coaxial cables (SYV, SYWV, SYFV) are suitable for closed-circuit monitoring and CATV engineering.
Special cable structure for SYWV(Y), SYKV CATV and broadband network: (coaxial cable) single oxygen-free round copper wire+physical foamed polyethylene (insulation)+(tin wire+aluminum)+polyvinyl chloride (polyethylene).
RVVP Shielded Wire: Copper Core PVC Insulated Shielded PVC Sheathed Flexible Cable Voltage 300V/300V 2-24 Core Usage: Instruments, meters, intercom and monitoring installation.
RG: Physical foamed polyethylene insulated access network cable is used to transmit data analog signals in coaxial optical fiber hybrid network (HFC).
KVVP: PVC sheathed braided shielded cable uses: signal transmission, control and measurement of electrical appliances, instruments and power distribution devices.
RVV sheath line (227IEC52/53) PVC insulated flexible cable uses: household appliances, small power tools, instruments and power lighting.
Flexible cable for AVVR PVC sheath installation
SBVV HYA data communication cable (indoor and outdoor) is used for telephone communication, connection of radio equipment and connection of junction box of telephone distribution network.
RV and RVP PVC insulated cables
RVS and RVB are suitable for household appliances, small electric tools, instruments, meters and electric lighting connecting cables.
BV and BVR PVC insulated cables Application: Suitable for fixed wiring of electrical instruments and power lighting.
Ribbed speaker cable (heating cable)
KVV PVC insulated control cable uses: signal transmission, control and measurement of electrical appliances, instruments and distribution devices.
SFTP twisted pair transmission telephone, data and information network
UL2464 computer connecting line
VGA display line
SYV coaxial cable wireless communication, broadcasting, monitoring system engineering and related electronic equipment (including integrated coaxial cable) for transmitting radio frequency signals.
Coaxial cable for elevator.
Copper core PVC insulated and sheathed copper wire braided computer control cable
-= Regular cable =-Specification and model
Friday, April 3, 2007, 065438+ 0 pm
Specification, model, name and scope of use
-= Ordinary cable =-
VV VLV
Vyvilli
Insulating polyvinyl chloride
Polyethylene sheathed power cable
Laying indoors, in tunnels and pipelines.
Cable can't bear mechanical external force.
VV22 VLV22 VV23 VLV23
Pvc insulated PVC polyethylene
Power cable armored with olefin sheathed steel belt
Directly buried soil indoors and in tunnels.
Soil and cables can withstand mechanical external forces.
VV32 vlv 32 VV33 vlv 33 VV42 vlv 42 VV43 vlv 43
Insulating polyvinyl chloride
Polyethylene sheathed steel wire armored power cable
Laying in high drop area, the cable can
Bear mechanical external force and considerable tensile force
YJV YJLV
YJY YJLY
XLPE insulated PVC
Polyethylene sheathed power cable
Laying indoors, in tunnels and pipelines.
Cable can't bear mechanical external force.
YJV22 YJLV22 YJV23 YJLV23
XLPE insulated PVC
Polyethylene sheathed steel belt armored power cable
Directly buried soil indoors and in tunnels.
Soil and cables can withstand mechanical external forces.
yjv 32 yjlv 32 yjlv 33 yjlv 33 yjlv 42 yjlv 42 yjlv 43 yjlv 43
XLPE insulated PVC
Polyethylene sheathed steel wire armored power cable
Laying in high drop area, the cable can
Bear mechanical external force and considerable tensile force
KVV KVVR
KVY KVYR
Insulating polyvinyl chloride
Polyethylene sheathed control cable
Laying indoors, in cable trenches and pipelines.
Inside and underground.
KVV22 KVV23
Insulating polyvinyl chloride
Polyethylene sheathed steel belt armored control cable
Laying indoors, in cable trenches and pipelines.
Indoors and underground, cables can withstand mechanical external forces.
Function.
KVVP KVVP2 KVVRP
PVC insulated PVC sheathed copper tape
Copper wire braided shielded control cable
Laying indoors, in cable trenches and pipelines.
Inside and underground, cables have anti-interference ability.
KYJV KYJVR KYJY KYJYR
XLPE insulated PVC
Polyethylene sheathed control cable
Laying indoors, in cable trenches and pipelines.
Inside and underground.
KYJV22 KYJV23
XLPE insulated PVC
Polyethylene sheathed steel belt armored control cable
Laying indoors, in cable trenches and pipelines.
Indoors and underground, cables can withstand mechanical external forces.
Function.
KYJVP KYJYP2 KYJYRP
XLPE insulated PVC
Polyethylene sheathed copper tape
Copper wire braided shielded control cable
Laying indoors, in cable trenches and pipelines.
Inside and underground, cables have anti-interference ability.
JKV JKLV
JKY JKLY
JKYJ JKLYJ
PVC/PE
XLPE insulated overhead cable
Used for overhead transmission and other places.
JKTRYJ
Soft copper core XLPE insulated overhead cable
Used for transformer down lead.
JKLYJ/Q
Crosslinked polyethylene insulated light overhead cable
Used for overhead transmission and other places.
JKLGYJ JKLGYJ/Q
Steel core aluminum stranded XLPE insulated overhead cable
Used in places such as overhead power transmission,
And can bear considerable tensile force.
LJ LGJ
Aluminum stranded wire and steel core aluminum stranded wire
Used for overhead fixed laying.
-= Special cable =-
Zr -X
flame retardant cable
Laying in places with flame retardant requirements.
GZR cable laying has particularly high flame retardant requirements.
Location.
GZR X
Oxygen barrier flame retardant cable
WDZR-X
Low smoke halogen-free flame retardant cable
Low-smoke halogen-free flame-retardant laying
If required, the GWDZR cable shall be laid in the specified location.
Find a field of low smoke and halogen-free flame retardancy.
Institute.
GWDZR-X
Low-smoke halogen-free flame retardant cable with oxygen barrier layer
NH-X
flame retardant cable
Indoor laying with fire resistance requirements.
In tunnels and pipelines, GNH cables should have fire resistance.
Outdoor places requiring high flame retardancy.
GNH X
Oxygen barrier fire-resistant cable
WDNH-X
Low smoke halogen-free fire-resistant cable
Laying in low smoke and halogen-free fire resistance requirements
In indoor, tunnel and pipeline, GWDNH is electrified.
In addition to the requirements of low smoke and halogen-free flame retardant,
Places with high requirements for flame retardant performance.
GWDNH-X
Low smoke halogen-free fire-resistant cable with oxygen barrier property
FS-X
Waterproof optical cable
The groundwater level is high all the year round,
Areas with high waterproof requirements.
H-X
Cold-resistant cable
Being in a low temperature environment all the year round,
Areas with high requirements for low temperature resistance.
FYS X
Environment-friendly termite-proof and rat-proof cable
Used in areas where termites and rats are seriously harmful.
And power cables in areas with flame retardant requirements,
Control cable.
- Previous article:What do you say if you don’t visit a patient and give a red envelope?
- Next article:Why are there always advertisements in class?
- Related articles
- To save the gunman's ex-boyfriend
- How to send international short messages?
- What is SMS?
- Friends wish the warm words of traveling abroad.
- Recently, I have received short messages announcing Taobao activities every day. How to shield?
- Is the message at the beginning of 1063 credible?
- Guiyang bank can't open online banking
- What does Xiamen Airlines actually mean by taking Changlong Airlines?
- Where can I find deleted messages?
- How to treat the record of inviting members of the home network?