Joke Collection Website - Bulletin headlines - Provisions of oil depot management system
Provisions of oil depot management system
(a) The oil depot should have fire-fighting facilities that meet the fire-fighting requirements, and must be equipped with sufficient fire-fighting equipment, and always be in a good standby state. (2) Warning signs such as "No Fireworks" should be hung at the entrance of the oil depot, and kindling should be handed over when entering the oil depot. (three) all electrical facilities in the oil depot should be explosion-proof, and the power supply circuit must be hidden wires or cables; There must be no overhead lines. (four) the oil depot should be kept clean, and other flammable items and sundries are not allowed to be stored. ⑤ Oil tank grounding wire and electrical equipment grounding wire should be installed separately. (6) All electrical equipment in the oil depot should be overhauled without power failure, and supervised by special personnel. (7) Oil depot staff should understand the properties of turbine oil and insulating oil and the relevant provisions on fire and explosion prevention, and unfamiliar personnel should be given safety education before they can participate in the operation and maintenance of the equipment. (eight) when the tanker is unloading oil, it is forbidden to put rubber pipes or iron pipes with iron wires into the oil unloading port. (9) When opening manholes and oil covers of oil tanks and drums, measuring oil level or sampling operations, it is forbidden to use iron tools to prevent sparks and fires. (10) When opening the sealing cover of the tanker, it is forbidden to knock with iron. When unloading oil, the tanker and the oil depot should be attended by special personnel to prevent the mixing of turbine oil and insulating oil. (eleven) often patrol when unloading oil to prevent running, running, dripping and oil leakage. (12) The oil depot should be well ventilated, and combustible gas should be removed in time. (13) The oil filter should strictly abide by the equipment operation and use regulations, and closely monitor the oil temperature with infrared thermometer to prevent the oil temperature from being too high. (14) Check the respirator, oil level gauge, valve and manhole door of the fuel tank every week, report any problems found and handle them in time. (15) The return oil from unit maintenance should be pumped into the running oil tank, and it can only be pumped into the clean oil tank after being treated as qualified. (16) Before maintenance, ensure that the equipment to be maintained is reliably isolated from the operating system. When maintaining, tools made of non-ferrous metals should be used as much as possible. If iron tools are used, measures should be taken to prevent sparks, such as oiling. (seventeen) when hot work is needed, a hot work ticket should be handled. During electric welding and flame welding, the electric welding and flame welding equipment shall be parked at the designated place. It is forbidden to use electric leakage and air leakage equipment. The live wire and grounding wire should be complete and firm, and it is forbidden to replace the grounding wire and fixed grounding point with iron bars. The grounding wire of electric welding machine should be connected to the equipment to be welded, and the grounding point should be close to the welding site. Long-distance grounding loop is not allowed. (18) When conducting naked fire operation in the oil tank, all piping systems leading to the oil tank shall be isolated, and the piping flanges shall be removed for ventilation. The inside of the fuel tank should be cleaned and well ventilated. (nineteen) when cleaning the fuel tank, the exhaust fan and axial fan should be turned on for ventilation. Sponge and gray surface should be used when cleaning, and materials with high fiber content and easy to fall off such as white cloth should not be used. The voltage of running lights used shall not exceed 12V. The guardian should be on the scene at any time and must not leave. (2 1) When electric welding and fire welding are carried out on the pipeline, the flange near the oil tank should be communicated with the atmosphere and separated by insulating materials, and the accumulated oil in the pipeline should be washed away to release residual gas. (twenty-two) oil drums should be numbered when filtering oil, and the type, source and time of oil should be indicated on the label, and waste oil drums should be clearly marked. Waste oil drums and clean oil drums should be divided into obvious storage areas.
legal ground
Regulations on safety management of oil depots
Article 4 Post personnel must learn the three rules before taking up their posts and be familiar with job responsibilities and professional rules;
Article 5 There shall be no kindling when entering the post, and fireworks and firecrackers are strictly prohibited in the reservoir area;
- Related articles
- Countless scenery, endless beautiful scenery, Hunan’s top ten characteristic cultural tourism towns
- Epidemic heart-warming copywriting
- Personal slogan to clean the cup every time you use it.
- There is often a saying similar to this in Buddhist scriptures: Buddhism mentioned by the Buddha is not Buddhism, but also a famous Buddhism. How should this be understood?
- Spring outing inspirational banner slogan?
- Lan Fan medical brand slogan
- How to understand "the first meeting of the first committee" and "the first party congress of xx city (county)"
- Do you want to be a coward all your life or be supported by thousands of people? Even if you are a devil. It takes more than courage. Who said that?
- Graffiti (Chinese words) detailed information
- Xinyang countryside land right confirmation zero distance